States
CaliforniaAvailable
FloridaAvailable
ArizonaAvailable
TexasAvailable
GeorgiaAvailable
NevadaAvailable
ColoradoAvailable
WashingtonAvailable
North DakotaAvailable
MaineAvailable
MarylandAvailable
MassachusettsAvailable
AlabamaAvailable
OhioAvailable
OklahomaAvailable
OregonAvailable
PennsylvaniaAvailable
Rhode IslandAvailable
South CarolinaAvailable
New HampshireAvailable
MichiganAvailable
VermontAvailable
IdahoAvailable
LouisianaAvailable
MinnesotaAvailable
MississippiAvailable
AlaskaAvailable
VirginiaAvailable
ArkansasAvailable
New YorkAvailable
All states →
Projects
152 project guides — open the list

Bathroom Remodel — Arizona license requirements

Verified 2026-10-023 official sources2 classification relations1 scope assertionIndexation gate: passed

01 The project

The starting point is the work itself — Bathroom Remodel in Arizona. The job determines which trades are involved, and the trades determine which license classifications may be required.

ComponentTrade
PlumbingPlumbing
ElectricalElectrical
TileTile
FramingFraming
DrywallDrywall
PaintingPainting

02 Jurisdiction

This project is evaluated for Arizona — a contractor license issued by the Registrar of Contractors to a BUSINESS (sole proprietorship, partnership, LLC or corporation) under A.R.S. Title 32, Chapter 11, qualified by a person with the statutory four years of experience, plus the LOCAL layer: building permits are issued by the city or county, and the §32-1121(A)(14) exemption itself turns on whether a local permit is required. Arizona jurisdiction page.

Limitation — the local layer is not researched

City and county permit fees, plan-review timelines and any locality-level registration were not verified for any Arizona jurisdiction beyond the documented City of Phoenix example — LOCAL_AUTHORITY_REQUIRED. State requirements are not the complete story for any locality.

03 Trade → license

Relations below are recorded per state — only this jurisdiction's classifications are shown.

Trades involved: Plumbing, Electrical, Tile, Framing, Drywall, Painting.

  • May require B-3 — General Remodeling and Repair Contractor confirmed S-AZ-ROC-CLASS rule AZ-REMODEL-TRADES
    B-3 General Remodeling and Repair covers remodeling or repair of an existing residential structure; rule AZ-REMODEL-TRADES encodes its verbatim subcontract list — a B-3 holder subcontracts electrical, plumbing, mechanical, boilers, pools, spas and water wells unless also holding that specialty (A.R.S. §32-1121(B): a trade license covers in-scope work without a second license).
  • Component basis R-37 — Plumbing, Including Solar (residential) confirmed S-AZ-ROC-CLASS
    Plumbing component basis: R-37 Plumbing, Including Solar covers water and gas piping, fixtures and vents — the classification a plumbing subcontractor on this project must hold (or the specialty a B-3 holder adds to do the work in-house). Commercial counterpart C-37 is documented on the classifications page; its verbatim scope includes hot-water supply systems up to 30 PSIG / 220°F.

04 Scope

What the official sources say about the work involved — typed assertions, never a boolean "covers". Interpretations are marked as such.

  • Requires another classification B-3 Subcontracting Of Electrical Plumbing Mechanical Boiler Pool Spa And Water Well Work (requires) ROC B-3 scope (roc.az.gov/license-classifications) S-AZ-ROC-CLASS
    Verbatim: a B-3 General Remodeling and Repair licensee subcontracts electrical, plumbing, mechanical, boilers, pools, spas and water wells unless also holding that specialty — rule AZ-REMODEL-TRADES encodes both branches. A.R.S. §32-1121(B) independently provides that a license in a particular trade covers mechanical or structural service within its own scope (REQ-AZ-INTRA-TRADE-001).

05 Requirements

RequirementKindStatementSource
Who needs an ROC license: $1,000 threshold OR any required permit
roc.az.gov/license-classifications (read 2026-10-02); A.R.S. §32-1121(A)(14)
licenseAny business which contracts or offers to contract to build, alter, repair, add to, subtract from, improve, move, wreck or demolish any building (including utility service line connections, metering devices, sewer lines and mechanical or structural service, plus subcontractors, floor-covering and hardscape contractors and construction managers) must be a licensed contractor; generally, if labor and materials exceed $1,000 OR a permit is required (regardless of the price of labor and materials), then a license is required (Arizona Registrar of Contractors; A.R.S. §32-1121).S-AZ-ROC-CLASS
Source S-AZ-ROC-CLASS — Arizona Registrar of Contractors (ROC)

License Classifications | Arizona Registrar of Contractors — roc.az.gov/license-classifications (read 2026-10-02); A.R.S. §32-1121(A)(14)

https://roc.az.gov/license-classifications

Retrieved 2026-10-02 · last verified 2026-10-02

Read verbatim 2026-10-02 (HTTP 200). Source of: the $1,000 / permit licensing threshold quote; the business-vs-qualifying-party credential model; the residential/commercial/dual classification axis; and the verbatim scope text of every seeded classification (B, B-2, B-3, R-11, R-37, R-39, R-42 incl. the 10% substrate rule, R-61 $50,000 cap, R-62 $5,000 cap + no-structural limit, C-11, C-37, CR-11, CR-37, CR-39, CR-42). The page also carries the FAQ whose 'exceed $1,000' phrasing conflicts with the statute at the exact boundary (CONFLICT-AZ-002). Per-classification requirement PDFs linked from this page were blocked by a Cloudflare interstitial and are NOT used.

A trade license covers in-scope mechanical/structural service — no second license
A.R.S. §32-1121(B)
licenseA.R.S. §32-1121(B): a license issued in a particular trade already covers mechanical or structural service work performed within the scope of that trade — no second license is required for in-scope work.S-AZ-1121
Source S-AZ-1121 — Arizona State Legislature (azleg.gov)

A.R.S. §32-1121 — Persons not required to be licensed; penalties; applicability — A.R.S. §32-1121(B)

https://www.azleg.gov/ars/32/01121.htm

Retrieved 2026-10-02 · last verified 2026-10-02

Full text retrieved VERBATIM 2026-10-02 (HTTP 200). Source of: the (A)(14) mini-job exemption (aggregate contract price 'is less than $1,000', casual/minor nature, and the three disqualifiers — local permit required, larger-operation/evasion splitting, advertising without 'not a licensed contractor'); (A)(5) owner-builder; (A)(4) and (A)(9) finished-products exemptions; (D)(1) fire-safety and (D)(2) gas-connection carve-outs from exemptions (4), (9) and (14); (B) a trade license covers mechanical/structural service within its own scope.

Building permits are LOCAL — state licensing does not answer the permit question
phoenix.gov/business/construction-permits-planning.html (read 2026-10-02); A.R.S. §32-1121(A)(14)(a)
permitThe A.R.S. §32-1121(A)(14) exemption itself turns on whether 'the performance of the work requires a local building permit', and local jurisdictions issue the permits: the City of Phoenix states construction permits are needed for building new homes and making additions or updates to existing ones, with city-run plan review, inspections and fee information, and its permit-issuance sheet states 'City law requires construction projects to be performed by State-licensed contractors.'S-AZ-PHX-PERMIT
Source S-AZ-PHX-PERMIT — City of Phoenix Planning & Development Department

Construction Permits and Planning | City of Phoenix — phoenix.gov/business/construction-permits-planning.html (read 2026-10-02); A.R.S. §32-1121(A)(14)(a)

https://www.phoenix.gov/business/construction-permits-planning.html

Retrieved 2026-10-02 · last verified 2026-10-02

Read 2026-10-02 (HTTP 200). Local permit LAYER example only: 'Construction permits are needed for building new homes and making additions or updates to existing ones', with city-run plan review, inspections and fee information; the city's permit-issuance requirement sheet states 'City law requires construction projects to be performed by State-licensed contractors.' No other locality was researched and no local fee amount, timeline or registration process is published (LOCAL_AUTHORITY_REQUIRED).

06 Rule: AZ-REMODEL-TRADES

Remodel subcontract rule for a B-3 holder: electrical, plumbing, mechanical, boiler, pool, spa and water-well work must be subcontracted to an appropriately licensed contractor UNLESS the B-3 holder also holds that specialty (A.R.S. §32-1121(B) covers in-scope trade work).

OutcomeConclusionCaveats
subcontract-trade-worktrade_work_must_be_subcontracted
  • Only the B-3 branch is evaluated: this rule does not decide whether a license is required at all (the $1,000 / permit threshold governs that).
  • A.R.S. §32-1121(B): a license in a particular trade covers mechanical or structural service within the scope of that trade — a specialty holder does its own in-scope work without a second license.
  • The local permit layer (plan review, inspections, permit fees) remains LOCAL_AUTHORITY_REQUIRED.
trade-specialty-heldtrade_work_may_be_performed_in_house
  • 'remodel_trade_specialty_held = true' must refer to the SPECIFIC trade of the component being evaluated (plumbing for a bathroom rough-in, electrical for the circuits, and so on).
  • Work outside the specialty's own classification scope still requires its own contractor — scope, not price, decides.

Rule confidence: confirmed. Missing inputs produce NOT_DETERMINED — never a forced answer. Sources: S-AZ-ROC-CLASSS-AZ-1121

07 The B-3 subcontract list

ComponentPath when the holder is B-3 onlyClassification
Plumbing rough-in and fixturessubcontract (unless B-3 + R-37)R-37
Electrical (circuits, devices)subcontract (unless B-3 + R-11)R-11
Mechanical / HVACsubcontract (unless B-3 + R-39)R-39
Tile, framing, drywall, paintinginside B-3 (incl. the R-7 carpentry scope)B-3

The left column is the verbatim B-3 scope list (electrical, plumbing, mechanical, boilers, pools, spas, water wells) mapped to the specialty codes the ROC publishes for those trades; A.R.S. §32-1121(B) provides that a license in a particular trade covers in-scope mechanical or structural service without a second license. S-AZ-ROC-CLASS S-AZ-1121

08 Local permit layer

Whether a license is required can turn on whether a LOCAL building permit is required for the work (A.R.S. §32-1121(A)(14)(a)); permits, their fees, plan review and inspections belong to the city or county — the City of Phoenix documents its own process and states that city construction projects must be performed by state-licensed contractors. S-AZ-PHX-PERMIT

Verify the license status that actually applies on the official lookup before relying on any outcome here: ROC Contractor Search S-AZ-ROC-SEARCH

Source S-AZ-PHX-PERMIT — City of Phoenix Planning & Development Department

Construction Permits and Planning | City of Phoenix — phoenix.gov construction permits; A.R.S. §32-1121(A)(14)(a)

https://www.phoenix.gov/business/construction-permits-planning.html

Retrieved 2026-10-02 · last verified 2026-10-02

Read 2026-10-02 (HTTP 200). Local permit LAYER example only: 'Construction permits are needed for building new homes and making additions or updates to existing ones', with city-run plan review, inspections and fee information; the city's permit-issuance requirement sheet states 'City law requires construction projects to be performed by State-licensed contractors.' No other locality was researched and no local fee amount, timeline or registration process is published (LOCAL_AUTHORITY_REQUIRED).

Evidence

S-AZ-1121statute
Arizona State Legislature (azleg.gov)
A.R.S. §32-1121 — Persons not required to be licensed; penalties; applicability
https://www.azleg.gov/ars/32/01121.htm
verified 2026-10-02retrieved 2026-10-02
S-AZ-PHX-PERMITboard page
City of Phoenix Planning & Development Department
Construction Permits and Planning | City of Phoenix
https://www.phoenix.gov/business/construction-permits-planning.html
verified 2026-10-02retrieved 2026-10-02
S-AZ-ROC-CLASSboard page
Arizona Registrar of Contractors (ROC)
License Classifications | Arizona Registrar of Contractors
https://roc.az.gov/license-classifications
verified 2026-10-02retrieved 2026-10-02

Verification

Page last verified
2026-10-02
newest verification date across the sources this page depends on
Policy reviewed
2026-10-02
policy: index — Bathroom remodel — B-3 may_require with the verbatim subcontract list (AZ-REMODEL-TRADES) and the R-37 plumbing component basis, all sourced.
Rules applied
1
AZ-REMODEL-TRADES